Washworld Razor – quick reference guide

INPUTSTERMINALFROM RAZOR
1 – Wash Status1911/okPos@output crd
2 – Gate loop signal (if used)2
3 – Out of Service31306
4 – n/a4
5 – Photo Eye5615 (UB photo eye)
OUTPUTSTERMINALTO RAZOR
Wash 1 – Bronze1 N.O.800
Wash 2 – Silver2 N.O.801
Wash 3 – Gold3 N.O.802
Wash 4 – Platinum4 N.O.803
Buy Up 15 N.O.810
Buy Up 26 N.O.811
Buy Up 37 N.O.812
Buy Up 48 N.O.813

Notes:

1) Connect the 24VDC Negative from 302 to the Sealevel power input on the left side power block on the rear GND and to the common terminal on the first input block on the front of the Sealevel. Also connect 24VDC Negative to wash output block commons.
2) Connect the 24VDC Positive from 301 to the Sealevel power input on the left side power block in the 9-30 VDC and to common terminal on 2nd input block.
3) Connect “Wash Status” signal wire to the signal (coil) side of the relay.
4) Set Dencar Customer Management Portal Sealevel to 2-wire out of service signaling.
5) On the Razor controller, set the wash status signaling to “Wash Done” signaling.