Petit 360i – quick reference guide

INPUTSTERMINALFROM PETIT #
1 – Wash status10016 / okPoS (Relay Coil) Signal / Left side
2 – Gate loop signal (if used)21034 (Signal / Left side)
3 – Out of service3not used on Petit
4 – n/a4
5 – Photo eye – option A5Entrance photo eye – 1022 (Signal / left side)
5 – Photo eye – option B5Dryer photo eye – 1023 (Signal / left side)
5 – Photo eye – option C5Aux exit door eye – 1043 (Signal / left side)
OUTPUTSTERMINALTO PETIT #
1 (Bronze)1 NO (Normally Open)1026
2 (Silver)2 NO (Normally Open)1027
3 (Gold)3 NO (Normally Open)1028
4 (Platinum)4 NO (Normally Open)1029
5 Bronze buy-up5 NO (Normally Open)1030
6 Silver buy-up6 NO (Normally Open)1031
7 Gold buy-up7 NO (Normally Open)1032
8 Gold buy-up8 NO (Normally Open)1033

Notes:

-Wires are 48″ long except the 0016 wash status wire is 88″ long
-Connect the 24VDC Negative to the Sealevel power input on the left side power block on the rear GND and to the common terminals on the input blocks on the front of the Sealevel.
-Connect the 24VDC Positive to the Sealevel power input on the left side power block on the 9-30 VDC and to the common terminals on the output blocks on the front of the Sealevel.

Petit HMI Settings:

Wash in Use Cycle – Set: “High While Wash in Use”
14.00: How Long to Delay the POS Screen From Changing to Welcome
15.00: How Long to Keep the Signal High After Screen Delay to Simulate WIU and Wash
ENABLED: Use Cycle Signal as “Out of Service” (OFF 1 sec, ON 1 sec, then HOLD ON)